REPLACEMENT
HINT:
1. REMOVE POWER OUTLET SOCKET ASSY CTR
(a) Turn the socket in the circumference direction as shown in the illustration, disengage the claw between the socket and the power point socket cover, and push out the socket to the room side.
2. INSTALL POWER OUTLET SOCKET ASSY CTR
(a) Align the socket with the notch on the power point socket cover CTR and install the power socket assy CTR by pushing it in as hard as possible.
Inspection
1. INSPECT THERMOSTAT
HINT:
The valve opening temperature is stamped on the thermostat.
(a) Immerse the thermostat in water and gradually heat the
water.
(b) Check the valve opening temperature.
Valve opening temperature: 80 to 84 C (176 to 183 F)
If the valve opening temperature is ...